Super Anchor Bolt-Thru Cast Loop Top Commercial Anchor
Original price was: $168.00.$101.50Current price is: $101.50.
51 in stock
Description
Super Anchor Lanyards and Connectors
Super Anchor Bolt-Thru Cast Loop Top Commercial Anchor
The Super Anchor 1093 is a cast loop top commercial fall protection anchor with a 2.0 inch inside diameter loop. It bolts through or field welds to a wood or concrete substrate as a single-user anchorage point, and is available in hot dip galvanized or 316 stainless steel.
The cast loop is rated to a minimum 10,000 pound casting strength and a minimum 5,000 pound bolt-attached strength, for one worker up to 340 pounds. Choose HDG or 316 stainless at checkout.
340 lbMax User Weight10,000 lbCasting Strength5,000 lbBolt Attached2.0 inLoop IDHDG or 316FinishOSHA 1926.502CompliantBolt-Thruor Field Weld1 PersonAnchorage
Who Needs This Product
The 1093 bolt-thru loop top is a permanent single-user commercial anchor for roofers and building owners who need a rated loop top tie-off on wood or concrete. Complete the system with a full-body harness, a connecting device, and 5/8 inch grade 8 attachment bolts (supplied by the installer).
Features
Cast loop top
A cast loop with a 2.0 inch inside diameter for connectors.
Bolt-thru or field weld
Installs bolted through the substrate or field welded.
HDG or 316 stainless
Choose hot dip galvanized or 316 stainless steel.
10,000 lb casting
Minimum 10,000 lb casting strength, 5,000 lb bolt attached.
340 lb capacity
One worker up to 340 pounds including tools.
OSHA compliant
Meets OSHA 1926.502 and 1910.140 anchorage requirements.
⚠
This is one component of a personal fall-arrest system. Stud bolt loop tops are not rated; use bolt-thru or field weld installation with certified 5/8 inch grade 8 bolts. Inspect before each use and confirm compatibility, capacity, and fall clearance. Run the Fall Protection Calculator below before you tie off.
Compliance Standards
ANSI Z359
American National Standards for connecting components and energy absorbers.
OSHA 29 CFR 1926.502
Federal construction fall protection requirements.
Typical Applications
Commercial roofingPermanent loop top tie-off.Concrete decksBolt-thru anchorage.Steel structuresField weld anchorage.MaintenanceLong term roof access.
How to Use the Bolt-Thru Loop Top
Follow the Super Anchor Safety instruction manual. The sequence below is an overview only.
- Inspect. Check for wear, cuts, distortion, corrosion, and gate or hardware function before each use.
- Confirm compatibility. Verify the component, harness, and anchor are compatible and rated.
- Connect. Make the connection and confirm every gate is fully closed and locked.
- Verify. Confirm the full system, capacity, and fall clearance.
- Use. Work within the rated limits of the system.
Inspection and Retirement
Inspect before each use, with a documented competent-person inspection at least annually. Remove the product from service for any condition below.
- Webbing or body: cuts, frays, abrasion, burns, corrosion, or distortion.
- Stitching: pulled, cut, or broken threads.
- Gates and locks: proper close and lock function.
- Fall indicators: any sign of deployment.
- Labels: illegible or missing markings.
Retire the anchor immediately after any fall-arrest event, or if any inspection point fails.
Fall ProtectionDistributors, LLC Free Tool · No Signup · OSHA 1926.502 Free Interactive Tool Fall Protection Calculator Pick your system. Run the math. Generate a plan. 1Pick Your SystemDetermine fall restraint vs. fall arrest based on your work surface, edge access, and clearance. 2Run the MathCalculate exact fall clearance required below the work surface for your setup. 3Generate a PlanGet a printable OSHA-compliant Fall Protection Plan structured around 29 CFR 1926.502(k). Run the Numbers and Stay Safe Launch the Calculator ›
Technical Specifications
| SKU | 1093-GB (HDG), 1093-SB (316sst) |
|---|---|
| Type | Cast loop top commercial anchor |
| Loop ID | 2.0 in |
| Casting strength | Minimum 10,000 lb |
| Bolt attached | Minimum 5,000 lb |
| Finish | HDG or 316 stainless |
| Capacity | 1 person, 340 lb |
| Standards | OSHA 1926.502 and 1910.140 |
| Warranty | Super Anchor Safety manufacturer warranty; see Warranty tab |
Frequently Asked Questions
What finishes are available?Hot dip galvanized (1093-GB) or 316 stainless steel (1093-SB). The specifications listed on this page outline the build details you need for your application. Keep the manufacturer instructions with the equipment so anyone using it can reference the approved procedures. Only trained workers should select, install, and use fall protection equipment for its intended application.How does it install?Bolted through the substrate or field welded, with certified 5/8 inch grade 8 bolts supplied by the installer. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off. Always inspect the product before each use and take it out of service if you notice any damage, deformation, or excessive wear.What is the loop size?A 2.0 inch inside diameter cast loop. See the Technical Specifications on this page for the exact materials, dimensions, and ratings. Before every use, confirm the product is compatible with the rest of your fall protection system and that you have adequate fall clearance below the work area.What is the strength rating?Minimum 10,000 lb casting strength and 5,000 lb bolt-attached strength. Refer to the specification table above for full details on construction, finish, and sizing. Before every use, confirm the product is compatible with the rest of your fall protection system and that you have adequate fall clearance below the work area.What is the maximum user weight?340 pounds including tools, for one person. See the Technical Specifications on this page for the exact materials, dimensions, and ratings. A qualified person should verify that the installation and the overall system meet the requirements of your specific job site. Store it in a clean, dry place away from heat and chemicals to help preserve its condition between uses.What standards does it meet?OSHA 1926.502 and 1910.140. Using the product within the limits described on this page helps keep your setup consistent with recognized fall protection practice. Only trained workers should select, install, and use fall protection equipment for its intended application. Always inspect the product before each use and take it out of service if you notice any damage, deformation, or excessive wear.Do I need a harness?Yes. The loop top is an anchorage point only and must be paired with a harness and connecting device. Confirm each component in the system is compatible and rated for the intended use before connecting to it. Store it in a clean, dry place away from heat and chemicals to help preserve its condition between uses.
Super Anchor Bolt-Thru Loop Top Submittals and Documentation
Super Anchor Loop Top Manual 2019 (PDF)Loop top installation, capacity, and inspection. Super Anchor CRA Manual 2023 (PDF)Commercial roof anchor installation and inspection. Super Anchor CRA Horizontal Lifeline Rigging Manual (PDF)HLL rigging for commercial anchors. Horizontal Lifeline Manual (PDF)HLL system rigging, spans, and clearances. Super Anchor Warranty and Compliance Statement (PDF)Manufacturer warranty and standards compliance.
Related Super Anchor Products
- Super Anchor lanyards and connectors
- Super Anchor harnesses
Specifying Commercial Anchors?
Substrate, finish, and load all affect the anchor choice. Confirm your project with us and we will help match the right loop top.
Call 863-703-4522 to talk to a fall protection specialist.